Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 50(5): 743-750, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38413294

RESUMO

OBJECTIVE: An adaptive harmonic separation (HS) technique is proposed to overcome the limitations in conventional filtering techniques for ultrasound (US) tissue harmonic imaging (THI). METHODS: Based on expectation-maximization source separation, the proposed HS technique adaptively models the depth-varying fundamental and harmonic components in the frequency domain and separates the two by applying their calculated posterior probabilities. Phantom experiments with a Tx center frequency of 2 MHz are conducted to evaluate the proposed HS-based US THI schemes. RESULTS: The phantom images show that the proposed single-pulse THI scheme utilizing the HS technique provides not only an average improvement of 19.2% in axial resolution compared to the conventional bandpass filtering scheme but also similar image quality to that of the conventional pulse-inversion (PI) scheme which requires two Tx/Rx sequences for each scan line. Furthermore, when combined with the PI technique, the HS technique provides a uniform axial resolution over the entire 170 mm imaging depth with an average improvement of 17.1% compared to the conventional PI scheme. CONCLUSION: These results show that the proposed adaptive HS technique is capable of improving both the frame rate and the image quality of US THI.


Assuntos
Ultrassonografia , Ultrassonografia/métodos , Imagens de Fantasmas
2.
BMC Med Imaging ; 24(1): 36, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321373

RESUMO

BACKGROUND: Ultrasound imaging is the most frequently performed for the patients with chronic hepatitis or liver cirrhosis. However, ultrasound imaging is highly operator dependent and interpretation of ultrasound images is subjective, thus well-trained radiologist is required for evaluation. Automated classification of liver fibrosis could alleviate the shortage of skilled radiologist especially in low-to-middle income countries. The purposed of this study is to evaluate deep convolutional neural networks (DCNNs) for classifying the degree of liver fibrosis according to the METAVIR score using US images. METHODS: We used ultrasound (US) images from two tertiary university hospitals. A total of 7920 US images from 933 patients were used for training/validation of DCNNs. All patient were underwent liver biopsy or hepatectomy, and liver fibrosis was categorized based on pathology results using the METAVIR score. Five well-established DCNNs (VGGNet, ResNet, DenseNet, EfficientNet and ViT) was implemented to predict the METAVIR score. The performance of DCNNs for five-level (F0/F1/F2/F3/F4) classification was evaluated through area under the receiver operating characteristic curve (AUC) with 95% confidential interval, accuracy, sensitivity, specificity, positive and negative likelihood ratio. RESULTS: Similar mean AUC values were achieved for five models; VGGNet (0.96), ResNet (0.96), DenseNet (0.95), EfficientNet (0.96), and ViT (0.95). The same mean accuracy (0.94) and specificity values (0.96) were yielded for all models. In terms of sensitivity, EffcientNet achieved highest mean value (0.85) while the other models produced slightly lower values range from 0.82 to 0.84. CONCLUSION: In this study, we demonstrated that DCNNs can classify the staging of liver fibrosis according to METAVIR score with high performance using conventional B-mode images. Among them, EfficientNET that have fewer parameters and computation cost produced highest performance. From the results, we believe that DCNNs based classification of liver fibrosis may allow fast and accurate diagnosis of liver fibrosis without needs of additional equipment for add-on test and may be powerful tool for supporting radiologists in clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Ultrassonografia , Curva ROC , Redes Neurais de Computação , Fígado/diagnóstico por imagem
3.
Acta Pharm Sin B ; 13(12): 4983-4998, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38045059

RESUMO

Lipid-coated microbubbles are widely used as an ultrasound contrast agent, as well as drug delivery carriers. However, the two main limitations in ultrasound diagnosis and drug delivery using microbubbles are the short half-life in the blood system, and the difficulty of surface modification of microbubbles for active targeting. The exosome, a type of extracellular vesicle, has a preferentially targeting ability for its original cell. In this study, exosome-fused microbubbles (Exo-MBs) were developed by embedding the exosome membrane proteins into microbubbles. As a result, the stability of Exo-MBs is improved over the conventional microbubbles. On the same principle that under the exposure of ultrasound, microbubbles are cavitated and self-assembled into nano-sized particles, and Exo-MBs are self-assembled into exosome membrane proteins-embedded nanoparticles (Exo-NPs). The Exo-NPs showed favorable targeting properties to their original cells. A photosensitizer, chlorin e6, was loaded into Exo-MBs to evaluate therapeutic efficacy as a drug carrier. Much higher therapeutic efficacy of photodynamic therapy was confirmed, followed by cancer immunotherapy from immunogenic cell death. We have therefore developed a novel ultrasound image-guided drug delivery platform that overcomes the shortcomings of the conventional ultrasound contrast agent and is capable of simultaneous photodynamic therapy and cancer immunotherapy.

4.
Ultrasonography ; 42(2): 249-258, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36935599

RESUMO

PURPOSE: High-contrast tissue characterization of thermal ablation has been desired to evaluate therapeutic outcomes accurately. This paper presents a photoacoustic (PA) characterization of thermal tissue ablation in the visible spectrum, in which higher light absorbance can produce spectral contrast starker than in the near-infrared range. METHODS: Ex vivo experiments were performed to measure visible PA spectra (480-700 nm) from fresh porcine liver tissues that received a thermal dose in a range of cumulative equivalent minutes at 43°C (CEM43). The local hemoglobin lobe area between 510-600 nm and wholespectral area under the curve were evaluated to represent the transition of hemoglobin into methemoglobin (MetHb) in the target tissue. RESULTS: The thermal process below an estimated therapeutic CEM43 threshold (80-340 minutes) presented a progressive elevation of the PA spectrum and an eventual loss of local hemoglobin peaks in the visible spectrum, closer to the MetHb spectrum. Interestingly, an excessive CEM43 produced a substantial drop in the PA spectrum. In the spectral analysis, the visible spectrum yielded 13.9-34.1 times higher PA sensitivity and 1.42 times higher contrast change than at a near-infrared wavelength. CONCLUSION: This novel method of PA tissue characterization in the visible spectrum could be a potential modality to evaluate various thermal therapeutic modalities at high-contrast resolution.

5.
Ultrasonography ; 42(2): 343-353, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36935600

RESUMO

High-intensity focused ultrasound (HIFU) is an emerging therapeutic tool for the effective thermal ablation of pathological tissue. For accurate localization of the target and safe control of the HIFU dosage, real-time imaging guidance during the HIFU exposure is desired. Ultrasound imaging has the capability to guide clinicians toward a lesion in real time, but is not an ideal option, as HIFU application causes strong interference, thereby substantially distorting the images used for guidance. Thus, this study introduces singular value decomposition-based filtering capable of restoring ultrasound harmonic images from HIFU interference without undesirable spectral distortion. The results were experimentally validated with a custom-made phantom, indicating that this approach effectively eliminates HIFU-induced artifacts, which is essential for real-time monitoring of the therapeutic process.

6.
Bioengineering (Basel) ; 11(1)2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38275576

RESUMO

Low-complexity ultrasound systems are increasingly desired for both wearable, point-of-care ultrasound and high-end massive-channel ultrasound for 3-D matrix imaging. However, the imaging capabilities, including spatial resolution and contrast, could suffer as low complexity systems are pursued, which remains as an unresolved tradeoff. To mitigate this limitation, this study revisits the general structures of analog and digital beamformers and introduces a hybrid approach, referred to as analog-digital hybrid beamforming, to implement efficient ultrasound systems. The suggested hybrid beamforming takes two stages sequentially, where the first analog stage partially beamforms M-channel RF signals to N sum-out data (i.e., M-to-N beamforming), and the second digital stage beamforms N partial sums to single final beamformed data (i.e., N-to-1 beamforming). Our approach was systematically designed and implemented with only four major integrated circuits, which was capable of driving full 64-channel transmission and reception. The developed system was demonstrated with a customized 64-channel 1-D phased array using a commercial tissue mimicking phantom. From the phantom imaging results, signal-to-noise ratio, contrast-to-noise ratio, and full beam width at half maximum values were quantitatively evaluated. The demonstrated results indicate that the analog-digital hybrid beamforming can be applied to any type of array for sophisticated 3-D imaging and tiny wearable ultrasound applications.

7.
IEEE Trans Biomed Eng ; 69(8): 2679-2690, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35180073

RESUMO

OBJECTIVE: Although plane wave imaging (PWI) with multiple plane waves (PWs) steered at different angles enables ultrafast three-dimensional (3-D) ultrasonic imaging, there is still a challenging tradeoff between image quality and frame rate. To address this challenge, we recently proposed the aperiodic PWI (APWI) with mathematical analysis and simulation study. In this paper, we demonstrate the feasibility of APWI and evaluate the performance with phantom and in vivo experiments. METHODS: APWI with a concentric ring angle pattern (APWI-C) and APWI with a sunflower pattern (APWI-S) are evaluated. For experimental verification of the methods, the experimental results are compared with simulation results in terms of the spatial resolution and the mainlobe-to-sidelobe ratio. In addition, the performance of APWI is compared with that of conventional PWI by using a commercial phantom. To examine the potential for clinical use of APWI, a gallstone phantom study and an in vivo carotid artery experiment are also conducted. RESULTS: In the phantom study, the APWI methods provide a contrast ratio approximately 2-3 dB higher than that of PWI. In a gallstone experiment, the proposed methods yield 3-D rendered stone images more similar to the real stones than PWI. In the in vivo carotid artery images, APWI reduces the clutter artifacts inside the artery. CONCLUSION: Phantom and in vivo studies show that the APWI enhances the contrast without compromising the spatial resolution and frame rate. SIGNIFICANCE: This study experimentally demonstrates the feasibility and advantage of APWI for ultrafast 3-D ultrasonic imaging.


Assuntos
Cálculos Biliares , Artefatos , Artérias Carótidas/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Ultrassonografia/métodos
8.
ACS Appl Mater Interfaces ; 14(8): 9987-10000, 2022 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-35176852

RESUMO

Chemical reactions between homogeneous precursors are typically used to synthesize monodisperse nanoparticles with well-controlled size and morphology. It is difficult to predict the evolved nanostructures when using two heterogeneous precursors. In this study, three types of Mo-Te nanoparticles shaped like leaves, spindles, and rice grains (denoted respectively as nanoleaf, nanospindle, and nanorice) were obtained from dextrose-mediated proton-coupled electron transfer reaction between the solid polyoxomolybdate (POM) and the ionic tellurite anion as precursors. All produced nanoparticles had excellent optical absorption in the ultraviolet(UV)-visible(Vis)-near-infrared(NIR) regions, with only slight deviations among them. After confirming nanoparticles' photothermal conversion and photocatalytic activity at multiple wavelengths, the Mo-Te nanorice was tested as a potential agent for cancer treatment due to its minimum toxicity, excellent colloidal stability, and intrinsic anticancer effect. Excellent treatment efficacy and clearance were confirmed in vitro and in vivo. Due to their photoacoustic imaging capability, the injection of pristine nanoparticles could also realize phototheranostics without using additional drugs, probes, or photosensitizers.


Assuntos
Nanopartículas , Neoplasias , Técnicas Fotoacústicas , Humanos , Nanopartículas/química , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Técnicas Fotoacústicas/métodos , Fototerapia , Medicina de Precisão , Nanomedicina Teranóstica
9.
IEEE Trans Biomed Eng ; 69(9): 2817-2825, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35226597

RESUMO

OBJECTIVE: Two-dimensional (2D) photoacoustic (PA) imaging based on array transducers provide high spatial resolution in the lateral direction by adopting receive dynamic focusing. However, the quality of PA image is often deteriorated by poor elevational resolution which is achieved by an acoustic lens. To overcome this limitation, we present a three-dimensional (3D) image reconstruction method using a commercial one-dimensional (1D) array transducer. METHODS: In the method, the elevational resolution is improved by applying synthetic aperture focusing (SAF) technique along the elevational direction. For this, a commercially available 1D array transducer with an acoustic lens is modeled and appropriate synthetic focusing delay that can minimize the effect of the acoustic lens is derived by mathematical analysis. RESULTS: From the simulation and experiment results, it was demonstrated that the proposed method can enhance the image quality of PA imaging, i.e., elevational resolution and signal-to-noise ratio (SNR). CONCLUSION: 3D PA images with improved elevational resolution were achieved using a clinical 1D array transducer. SIGNIFICANCE: The presented method may be useful for clinical application such as detecting microcalcification, imaging of tumor vasculature and guidance of biopsy in real time.


Assuntos
Técnicas Fotoacústicas , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Técnicas Fotoacústicas/métodos , Razão Sinal-Ruído , Transdutores
10.
Sensors (Basel) ; 21(8)2021 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-33918047

RESUMO

Point-of-care ultrasound (POCUS), realized by recent developments in portable ultrasound imaging systems for prompt diagnosis and treatment, has become a major tool in accidents or emergencies. Concomitantly, the number of untrained/unskilled staff not familiar with the operation of the ultrasound system for diagnosis is increasing. By providing an imaging guide to assist clinical decisions and support diagnosis, the risk brought by inexperienced users can be managed. Recently, deep learning has been employed to guide users in ultrasound scanning and diagnosis. However, in a cloud-based ultrasonic artificial intelligence system, the use of POCUS is limited due to information security, network integrity, and significant energy consumption. To address this, we propose (1) a structure that simultaneously provides ultrasound imaging and a mobile device-based ultrasound image guide using deep learning, and (2) a reverse scan conversion (RSC) method for building an ultrasound training dataset to increase the accuracy of the deep learning model. Experimental results show that the proposed structure can achieve ultrasound imaging and deep learning simultaneously at a maximum rate of 42.9 frames per second, and that the RSC method improves the image classification accuracy by more than 3%.

11.
IEEE Trans Biomed Eng ; 68(5): 1690-1701, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32853148

RESUMO

OBJECTIVE: The ultrasound baseband in-phase/quadrature beamformer (IQBF) has been widely employed in medical ultrasound imaging to reduce the amount of channel data or to decrease the data rate of the beamforming process. The aim of this study is to assess the effect of the time and phase delay compensation accuracies on the IQBF and thereby to suggest the criteria for selecting the delay resolutions of the IQBF. METHODS: Mathematical models of the gain loss (GL) and sidelobe level (SL) in closed form are suggested, and the relationships between the parameters (time and phase delay resolutions of the IQBF and the signal bandwidth) and the errors (GL and SL) are investigated. The performance of the IQBF is compared with that of the traditional radio-frequency beamformer (RFBF). Simulation and phantom and in vivo experimental results are shown to corroborate the theoretical analysis. RESULTS AND CONCLUSION: Theoretical analysis and simulation and experimental results show that a phase delay resolution with a quantization step of 2π/64 is sufficient for phase compensation and that a time delay resolution with a sampling rate of 4f0 and 2f0 in the IQBF is sufficient for data with a -6 dB bandwidth of 50% and 25%, respectively, for similar performance as the RFBF with a sampling rate of 16f0, where f0 is the center frequency of the ultrasound signal. SIGNIFICANCE: The suggested criteria have the potential to be used for designing an efficient IQBF satisfying the desired specifications and beamforming accuracy.


Assuntos
Modelos Teóricos , Ondas de Rádio , Algoritmos , Simulação por Computador , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Ultrassonografia
12.
Sensors (Basel) ; 20(19)2020 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-33027916

RESUMO

Although plane wave imaging (PWI) has been extensively employed for ultrafast ultrasound imaging, its potential for sectorial B-mode imaging with a convex array transducer has not yet been widely recognized. Recently, we reported an optimized PWI approach for sector scanning that exploits the dynamic transmit focusing capability. In this paper, we first report the clinical applicability of the optimized PWI for abdominal ultrasonography by in vivo image and video evaluations and compare it with conventional focusing (CF) and diverging wave imaging (DWI), which is another dynamic transmit focusing technique generally used for sectorial imaging. In vivo images and videos of the liver, kidney, and gallbladder were obtained from 30 healthy volunteers using PWI, DWI, and CF. Three radiologists assessed the phantom images, 156 in vivo images, and 66 in vivo videos. PWI showed significantly enhanced (p < 0.05) spatial resolution, contrast, and noise and artifact reduction, and a 4-fold higher acquisition rate compared to CF and provided similar performances compared to DWI. Because the computations required for PWI are considerably lower than that for DWI, PWI may represent a promising technique for sectorial imaging in abdominal ultrasonography that provides better image quality and eliminates the need for focal depth adjustment.


Assuntos
Abdome/diagnóstico por imagem , Ultrassonografia , Artefatos , Humanos , Imagens de Fantasmas
13.
Artigo em Inglês | MEDLINE | ID: mdl-32070951

RESUMO

Sparse arrays have been studied mainly to reduce the large numbers of elements in 2-D arrays. However, they can also provide an effective means of miniaturizing ultrasound 1-D array systems for point-of-care applications. Although a variety of sparse array design strategies have been proposed, designing an optimum sparse array to simultaneously satisfy the system specification requirements and performance criteria remains a challenge. This article presents an analytical approach for the design of an optimum pair of periodic sparse arrays (PSAs), one for transmission and the other for reception. The approach is based on three newly derived theorems that describe the most important properties of the two PSAs forming the sparse array pair and their relationship pertaining to the overall beam pattern. The proposed approach can be used to design 1-D sparse array pairs with arbitrary sparseness factors while meeting given performance criteria. The computer simulation verified that the spatial resolution of a 64-element phased array can be obtained with a PSA pair consisting of transmit and receive sparse arrays, of which the number of elements is reduced to 32 and 22, respectively.

14.
Ultrasonics ; 102: 106030, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31785584

RESUMO

Passive acoustic mapping (PAM) is the current state-of-the-art imaging tool for monitoring cavitation activity during focused ultrasound therapy such as blood-brain barrier opening. However, PAM incurs huge computational complexity. To address this issue, frequency-domain PAM (FD-PAM) was proposed. Nevertheless, FD-PAM still requires a large number of fast Fourier transforms (FFTs) to produce the frequency components utilized for cavitation monitoring with PAM. Hence, in this paper, we proposes a frequency domain PAM method using passive Hilbert beamforming (PHB-PAM), which can significantly reduce the number of input samples for FFT by down-sampling the analytic signal of the received RF samples at each channel at a rate equal to the bandwidth of the frequency components of interest. The experimental results show that the proposed PHB-PAM provides comparable image quality to that of FD-PAM (correlation coefficient > 0.98). Additionally, the study experimentally verifies that the pre-processing block for generating the decimated analytic signal and FFT in PHB-PAM can be realized using lesser logic resources than FFT in FD-PAM when implemented in an FPGA. Especially, with 128-fold decimation, PHB-PAM reduces the amount of LUTs and DSP slices to implement the pre-processing block by 72.16% and 53.4%, respectively, compared to those of FD-PAM, which allows the 64-channel implementation of the pre-processing block in a low-cost single FPGA. Finally, a hardware-efficient architecture for the pre-processing block of PHB-PAM is described, which can be implemented by replacing the two lowpass filters of an off-the-shelf analog front-end component for ultrasound imaging with a pair of band-pass filters. If PHB-PAM is realized using such a component, it can truly minimize the computational complexity of FD-PAM.

15.
Sensors (Basel) ; 19(19)2019 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-31546705

RESUMO

This paper reports the feasibility of Nakagami imaging in monitoring the regeneration process of zebrafish hearts in a noninvasive manner. In addition, spectral Doppler waveforms that are typically used to access the diastolic function were measured to validate the performance of Nakagami imaging. A 30-MHz high-frequency ultrasound array transducer was used to acquire backscattered echo signal for spectral Doppler and Nakagami imaging. The performances of both methods were validated with flow and tissue-mimicking phantom experiments. For in vivo experiments, both spectral Doppler and Nakagami imaging were simultaneously obtained from adult zebrafish with amputated hearts. Longitudinal measurements were performed for five zebrafish. From the experiments, the E/A ratio measured using spectral Doppler imaging increased at 3 days post-amputation (3 dpa) and then decreased to the value before amputation, which were consistent with previous studies. Similar results were obtained from the Nakagami imaging where the Nakagami parameter value increased at 3 dpa and decreased to its original value. These results suggested that the Nakagami and spectral Doppler imaging would be useful techniques in monitoring the regeneration of heart or tissues.


Assuntos
Coração/fisiologia , Regeneração/fisiologia , Ultrassonografia/métodos , Animais , Aumento da Imagem , Peixe-Zebra
16.
Artigo em Inglês | MEDLINE | ID: mdl-31380753

RESUMO

Three-dimensional plane wave imaging (PWI) with a 2-D array has been studied for ultrafast volumetric imaging in medical ultrasound. Compared to 2-D PWI, 3-D PWI requires the transmission of an increased number of plane waves (PWs) to scan a volume of interest and achieve transmit dynamic focusing in both the lateral and elevational directions. To reduce the number of PW angles for a given 2-D angular range by mitigating the grating lobe level, we propose two aperiodic patterns of PW angles: concentric rings with a uniform radial interval and the well-known sunflower pattern. Both patterns are validated to provide uniform angle distributions without regular periodicity, and thereby reduce the grating lobe level compared to a periodic angle distribution with the same number of PW angles. Simulation studies show that the aperiodic patterns enhance the contrast of B-mode images by approximately 3-6 dB over all depths. This enhancement implies that the aperiodic angle sets can increase the volume rate by approximately 2-6 times compared to the periodic angle set at the same contrast and spatial resolution.


Assuntos
Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Algoritmos , Artefatos , Simulação por Computador , Imagens de Fantasmas , Transdutores
17.
J Acoust Soc Am ; 145(6): EL604, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31255107

RESUMO

The spatiotemporal accuracy of passive acoustic mapping (PAM) for monitoring in situ cavitation bubbles has not been assessed directly via optical means. Here, the cavitation bubbles are monitored from two image sequences obtained simultaneously with PAM and high-speed photography (HSP). The temporal accuracy of PAM for detecting cavitation nucleation and the spatial resolution for cavitation localization are compared with those measured from HSP. The results show that PAM has a temporal accuracy of 20 µs. Mean differences in the spatial locations of PAM and HSP are as small as 10.0 and 30.5 µm along the lateral and axial directions, respectively.

18.
Biomed Eng Lett ; 9(1): 119-125, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30956885

RESUMO

In this study, we sought to describe a novel imaging apparatus that is lightweight, inexpensive, and highly effective for use in colorectal diagnostic and treatment settings. Typical probes for use in colorectal ultrasonic imaging applications are developed for surgeons to diagnose and stage rectal tumors and image the rectum and anus. Here we outline a new technique and use it for colorectal imaging in an animal. This technique involves use of an ultrasound array module positioned along the axis of rotation such that improved rotation is possible. This module is in the shape of a linear rod with a rotary linear component that allows for emission of focused ultrasonic echo signals from a linear section of the probe. The usability of the transducer and rectal image quality are satisfactory in a porcine model with the technique proposed here, axial/lateral resolution as 0.96/2.24 mm with 6 dB applied through the contour map using the point spread function. When compared to currently available methods, this technique provides superior diagnostic 3D volumetric image quality with reduced acquisition time. Given this, the ultrasound device proposed here may prove a viable and preferable method to those currently available for urology and colorectal imaging applications.

19.
Sensors (Basel) ; 20(1)2019 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-31892233

RESUMO

In three-dimensional (3D) medical ultrasound imaging with two-dimensional (2D) arrays, sparse 2D arrays have been studied to reduce the number of active channels. Among them, sparse 2D arrays with regular or uniform arrangements of elements have advantages of low side lobe energy and uniform field responses over the entire field of view. This paper presents two uniform sparse array models: sparse rectangular arrays (SRAs) on a rectangular grid and sparse spiral arrays (SSAs) on a sunflower grid. Both arrays can be easily implemented on the commercially available or the custom-made arrays. To suppress the overall grating lobe levels, the transmit (Tx) and receive (Rx) array pairs of both the array models are designed not to have grating lobes at the same locations in the Tx/Rx beam patterns, for which the theoretical design rules are also proposed. Computer simulation results indicate that the proposed array pairs for both the SRAs and the SSAs achieve peak grating lobe levels below -40 dB using about a quarter of the number of elements in the dense rectangular array while maintaining similar beam widths to that of the dense array pair.

20.
J Acoust Soc Am ; 144(5): 2627, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30522306

RESUMO

Synthetic transmit focusing (STF) methods using unfocused waves or plane waves (PWs) have recently been investigated extensively. However, STF using PWs with a convex array (PWSTF-CA) has not been rigorously studied for high-resolution sector imaging. In this paper, the authors suggest an analytical model for accurate characterization of the spatial beam patterns of PWSTF-CA using a large range of either uniformly or non-uniformly distributed PW angles. On the basis of the model, a frame-based PWSTF-CA approach with non-uniform PW angles is suggested to achieve superior image quality at a higher frame rate than conventional transmit focusing (CTF). The analytical model can also be used for optimal selection of a set of PW angles to scan the entire sectorial field of view and its subsets employed for STF at each imaging point. The authors also investigate how to select transmit subarrays for each of the PWs to obtain the best spatial resolution. A theoretical analysis and simulations are conducted for the verification of the analytical model and the optimal utilization strategy of PWSTF-CA. The results indicate that the PWSTF-CA improves not only the frame rate but also the contrast, signal-to-noise ratio, and resolution compared with the CTF, as in the case of PWSTF with linear arrays.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...